********************************************************* * This firmware is for the following products: * * --------------------------------------------- * * HD9010TM HD9010TM-IRIG * ********************************************************* version 2.0 build 564 (May 29, 2015) --------------------------------------- - Reworked 6Hz locking mechanisms - Added Debug Window code to report 6Hz and 30Hz locking status - Fixed accuracy of parallel port 6Hz and 30Hz locking - Readjusted 24 to 30 cross jamming triggers - Fixed Aux LTC input reader modes and Generator Time anomalies - Corrected first pass into the menu system's sub menu does not flash display to indicate correct setting - Resolved crashes when entering GEN MODE menu item - Fixed crashes when ATC reader type is vitc but input ATC type is ltc - Resolved GTM won't stop at no code mute or hold condition - Fixed ATC generator is turned on after reboot - Corrected won't boot if COM1 baud rate set below 2400 - Unit crashes if a window falls below the bottom of the screen - ATC Generator turns on if ATC Generator type is changed - ATC Reader type always functions as LTC+VITC - Video LED stays on when input video disconnected - ATC Reader Modes and "No Code Run/Hold" functionality corrected - GUB value not consistent when GEN MODE is time data - ANC GEN cannot be turned on at some conditions - Corrected GTM won't stop completely at no code mute or hold condition - menu display timer incorrectly affecting non menu display modes - Removing the source time code mutes the output time code for only a few seconds - Anc Generator falsely creates a VITC2 packet when the GEN ATC TYPE is set to LTC only - On power up the first pass into the menu system's sub menu does not flash display to indicate correct version 2.0 build 241 (April 15, 2009) --------------------------------------- - Fixed preset mapping size bug - Fixed HANC inserter not handling existing RP-188 (SMPTE-12M-2) packets that appear BEFORE the audio control packets - Added VANC inserter On/Off Menu item - Fixed 720P video standards randomly phase locking to the genlock input, only works with bi-level inputs - Added 1080P/30 support Version 2.0 build 138 (June 6, 2006) ------------------------------------- - Added drop-frame conversion mode - Panel lockout process now involves SHIFT key - Added "VID:" current video standard display - Added IRIG no code present dynamics - Corrects NVRAM storage and restoration problems - Improved metadata protocol connectivity - Corrected display issues - Corrected COM1 baud rate issue Version 2.0 build 37 (July 12, 2005) ----------------------------------------------- - Added GPI transmission via RP-188 timecode support for 6 inputs. Valid on 7700PH4 boards - Added to the Front panel a GPI, COM1, and COM2 status display - extended the GPI status displays to 8 inputs. - Assigned default functions for 8 GPIs (consult manual) Version 2.0 build 01 (May 30, 2005) ----------------------------------------------- - Initial release for Harware revision REV 2 (7700PH4) - This and later versions will have dual hardware revision support. With the setting of the appropriate environment variables, they will run on both REV1 and REV 2 type hardware Version 1.2 build 201 (January 12, 2005) ---------------------------------------- - corrected a rare IRIG reader burn in bobble issue Version 1.2 build 190 (January 4, 2005) --------------------------------------- - added IRIG timecode reading capabilities (requires IRIG option hardware) - added IRIG information insertion into the RP-188 ANC data generator - added the capability to read back the ANC data containing the IRIG information - corrected a small drift error in the irig reader Version 1.2 build 44 (August 19, 2004) -------------------------------------- - added tri level sync genlock support - added No Code Jam support - fix for a jamming offset issue Version 1.2 build 1 (May 5, 2004) --------------------------------- - fix for jamming between different timecode rates Version 1.1 build 66 (February 25, 2004) ---------------------------------------- ***NOTE - This version of firmware requires new CPLD code to be loaded *** - fix for offset issue - fix for output rate of Auxillary LTC generator - fix to support and automatic switch between 1:1 and 1:1.001 standards Version 1.0 build 2065 (February 6, 2004) ----------------------------------------- - fix for video standard issue Version 1.0 build 1997 (December 10, 2003) ------------------------------------------ - fix to pass audio through the RP-188 inserter Version 1.0 build 1989 (November 14, 2003) ------------------------------------------ - fix for bypass power up issue Version 1.0 build 1988 (November 12, 2003) ------------------------------------------ - first release